de IK1IYU » Mer 27 Jan 2021 22:36
Hello Jean-Pierre,
I think to have found a bug in the last beta 02k of Scan&Tioune.
In my setup I use the B port of MiniTiouner-PRO2 for QO-100 reception.
All parameters are set ok into the .ini file (port=B, voltage=18V, 22KHz=off).
But, when the program start, the voltage on port B is switched to 13V and I can visually see that on the MiniTiouner LED...I must manually switch between 0V and back to 18V to start correct reception of the QO-100 beacon signal.
After that, every time I try to lock on a different signal on the spectrum (manually or automatically) the program switch back to 13V, and I have to repeat the manual switch between 0V and 18V.
All the previous versions still works without problem in the same configuration, so I think there is something wrong in the 02k.
I have not tried to change my settings to port A of the MiniTiouner-PRO2, but I believe that most users has that port set by default in the .ini file and anyone has reported my problem.
Thank you for the attention and for your excellent work.
73 de Piero, IK1IYU